Skip to main content

Search Results:

    There doesn't appear to be any pages that match your search. Try more general keywords, or just ask us!

    Search Results:

    Product Category Suggestions
      Pages
        Video

        Ultimate Efficiency and Professional Finish

        • MAX9 takes the definition of a busbar to next level with MAXBAR. MAXBAR helps to improve installation speed by up to 15 times when compared to using cables for feeding RCBOs
        • With MAXBAR, no cable connections are needed to feed final sub-circuits protected by an RCBO or AFDD - it picks up the active feed from the main switch and distributes both active & neutral across all types of Clipsal  RCBOs and AFDDs
        Description

        Clipsal MX9RC440 | 40A 4 Pole MAX9 RCCB | 30mA Type A

        The Clipsal MX9RC440 MAX9 product is a residual current circuit breaker (RCCB)..
        MX9RC440 is a 4P RCCB with 40A In rated current, a sensitivity of 30mA with A type protection class.

        RCD – Residual Current Devices

        Although Australia has one of the safest electrical systems in the world, accidents can still happen. A poorly maintained appliance, a person who innocently pushes something into a power socket or cuts through an electrical wire, a frayed cord, wet hands or carelessness with power tools are all situations that can lead to serious consequences.
        The benefits of residual current devices (RCDs) are well documented and the latest version of wiring rules (AS/NZS 3000:2018) makes it mandatory to have RCD protection for all final sub-circuits in residential applications.
        Amendment 2 of AS/NZS 3000:2018 makes it mandatory to have type A RCD (no type AC RCD) from May 2023 for additional safety. All RCDs under the MAX9 range are future-ready and already type A.

        How an RCD works
        The RCD works by constantly monitoring and comparing the current flow in both the Active and Neutral cables of an electrical installation.
        During normal operation, these Active and Neutral currents are in balance. However, should any current flow to Earth, an imbalance is created in these circuits. If this imbalance is sufficient, the RCD will cut the electrical supply.
        Apart from helping to protect people, RCD will also cut off power to expensive electrical equipment in the event of an electrical fault to Earth. This helps to protect appliances against costly damage and the installation against fire, resulting from faults of this nature.

        Features and benefits:

        • Covers all potential residential needs
        • Line and load can be top or bottom connected, ideal when cabling space is restricted or limited.
        • Lift-up terminals. helps to reduce chances of ‘hot spot’ in terminations with all cable strands are locked in
        • Compatible with MAX9 18 mm pin type busbar for connections to multiple MCBs
        • Double locking clip for ease of installation or removal from MAXBAR
        • The earth-leakage protection time delay is instantaneous.
        • The (Im) rated breaking and making short circuit capacity is 500A.
        • The (Inc/Ic) rated conditional rated short circuit current is 6kA.
        • The electrical endurance goes up to 4000 cycles and mechanical endurance is going up to 10000 cycles.
        • This product protects against electrical shock by direct or indirect contact and fire hazards.
        • It is also compulsory for all equipment in bathrooms, outdoors. As a high sensitivity residual current circuit breaker, it is recommended for all power sockets.
        • It has an RCM quality label.
        • The Ue rated operational voltage is 415VAC.
        • The operating frequency is 50Hz.
        • The Ui rated insulation voltage is 440VAC.
        • It has a Uimp rated impulse withstand voltage of 4kV.
        • It can be mounted on DIN rail for modular installation.
        • The width in 9mm pitches is 8.
        • The dimensions are (W) 72mm x (H) 85mm x (D) 75mm.
        • The product colour is white (RAL9003).
        • The product weight is 370g.
        • According to IEC 60529 standard, the degree of protection is IP20.
        • The pollution degree is 2.
        • This product complies with IEC 61008-2-1 and EN/IEC 61008-1 standards.

        (MX9RC440)

        Warranty

        Warranty starts from Invoice Date

        Domestic Use: 7 Year
        Commercial Use: 7 Year
        Warranty Method: Clipsal in home warranty

        Specifications

        These specifications and characteristics outline physical, mechanical, electrical details.

        Brand Clipsal by Schneider Electric
        SKU MX9RC440
        Barcode # 9311554813291
        Shipping Weight 0.3660kg
        Shipping Width 0.090m
        Shipping Height 0.080m
        Shipping Length 0.080m
        Shipping Cubic 0.000576000m3
        TYPE VALUE
        Type Circuit Protection
        Brand Clipsal by Schneider Electric
        Range Clipsal - Max9
        Rated Current (A) 40A
        Voltage (V) 415Vac
        Breaking Capacity 6kA
        Earth Leakage Sensitivity 30mA
        Earth Leakage Protection Class A-type
        Curve NA
        Poles 4P
        Tripping Standard
        Equivalent Max 4 Reference 4RC440/30
        Equivalent Hager Reference CDA440T
        Reviews
        0.0

        0 Reviews
        5 STARS
        0
        4 STARS
        0
        3 STARS
        0
        2 STARS
        0
        1 STAR
        0
        Be The First To Review This Product!

        Help other Sparky Direct users shop smarter by writing reviews for products you have purchased.

        Write a review